Cutting building management costs

May 2016 Security Services & Risk Management

Effective well-utilised building management systems (BMS) provide the core management tool required by facilities’ security, asset and SHE managers to ensure compliance with, and achievement of Green Lease requirements, SHE, insurance compliance, effective, security controls, monitoring of the energy management plans (EMP), and reports for the building management committee (BMC).

Christopher Cobb.
Christopher Cobb.

It enables facilities, security and SHE managers to provide the optimal working environment while minimising the costs to both property administrators and tenants. Effective BMS utilisation allows for optimal building performance by extending the operational life of equipment and systems through reducing loads and operating hours. Maintenance and capital costs are therefore reduced and less embedded energy is consumed through equipment replacement and upgrades. Equipment alarm and fault notification, reduces down time and consequential impact.

Industry jargon

BMS is also known as building automation systems (BAS), building management and control systems (BMCS), direct digital controls (DDC) and building controls. Other terms associated with control systems include:

• Supervisory, control and data acquisition (scada).

• Programmable logic controllers (PLC).

• Energy management system (EMS).

• Data gathering panels (DGP).

• Modbus, Lonworks, and Bacnet – all refer to communications protocols.

• ‘Front End’ – legacy term used to refer to the BMS operator workstation.

Most common current industry terms are:

• Building management system (BMS) or building management and control systems (BMCS).

What is a BMS?

BMS are 'intelligent' microprocessor-based controller networks installed to monitor and control a building’s technical systems and services such as air conditioning, ventilation, lighting and hydraulics. More specifically, they link the functionality of individual pieces of building equipment so that they operate as one complete integrated system. They are now installed in almost every major building or facility with the availability of direct integration into all other building services such as:

• Security.

• Access control.

• CCTV.

• Fire.

• Gas.

• Lifts and other life and safety systems.

Current generation BMS systems are now based on open communications protocols and are web enabled allowing integration of systems from multiple system vendors and access from anywhere in the world.

The role of the BMS

The most common primary function of the BMS is the control of a building’s heating, ventilation and air conditioning systems (HVAC) including;

• Air handling units.

• Chilled water plant.

• Cooling towers.

• Tenant condenser water.

• Heating water plant.

• Exhaust systems.

• Zone controls.

• Computer room AC.

• Control of building systems and services.

• Graphic user interface (GUI).

• Real-time monitoring of building operation and performance.

• Trending and logging of building operation and performance.

• Time scheduling of building systems.

• Fault management and alarming.

• Control application programming.

• User event management.

• Energy management and reporting.

• Building control applications.

Building control applications include the following:

• Zone temperature monitoring and control.

• Zone variable air volume (VAV) control to zones.

• Zone CO2 monitoring and control (air quality).

• Air handling unit supply air temperature control.

• Air handling unit supply air flow / pressure control.

• Main plant chiller and boiler sequencing.

• Toilet, car park, kitchen and general exhaust fan control.

• After hours building control.

Interaction with other building / facilities systems includes:

• Lighting network.

• Meter network.

• Emergency lighting network.

• PA network.

• CCTV network.

• Fire network.

• Access control network.

• Security network.

• DDC network.

• Other network.

Comparison of BMS capabilities

The capability of installed BMS systems varies from the most basic being virtually a time clock (a device which turns equipment on and off) to that of a highly sophisticated and flexible management tool. The additional software cost of a high-level system is not substantial. Additional costs of high-level BMS systems are mainly due to:

• Higher computer and data storage requirements.

• Connection of more sensing and monitoring points.

• Increased networking requirements.

• Building more graphics pages.

• Configuring a more sophisticated alarm system.

• Configuring external access and reporting.

A high level BMS system will:

• Fully support Green Lease tenant requirements.

• Fully support a wide range of best practice control strategies.

• Have a detailed suite of automated reports.

• Support simple set up of ad-hoc reports for maintenance or enhancement activities.

• Have an alarm hierarchy that flags relative importance of alarms.

• Not constrain use of improved equipment or strategies.

• Have capabilities that continue to be enhanced and evolved by supplier.

When the power and capabilities of a properly configured high-level BMS are fully utilised by maintenance staff, operators, and tenants, the payback period of the additional cost is normally very short. It can be less than one year, and is seldom more than five years from energy savings alone. Tenant satisfaction is generally higher through better environmental control, and ease of adjusting functional usage of the building.

A basic system has limited fault analysis capabilities and will seldom identify energy intensity improvements, nor will it facilitate their implementation. Failures causing excessive consumption or poor environmental conditions will seldom be clearly identified. While cheap, a basic system may lead to higher maintenance and energy costs. When renting an existing building an inadequate BMS must be rated as a very negative factor in negotiations.

When a building has been completed the impact of its structure on its energy consumption performance is normally fixed until refurbishment occurs. Base building and tenant light and power energy consumption can however be increased or decreased by the performance of both building systems and tenants.

A BMS will show increases in energy use due to equipment failure or adjustments to operating parameters. For example, heating valves opening when the building requires cooling or whole floors of lights being left on for extended periods of time due to cleaning activity. A BMS may also indicate that air-conditioning is starting up hours before the building is fully occupied due to activities of security staff. With this information in hand, the building manager may be able to rectify such issues through consultation or engineering solutions.

System maintenance

The BMS should be maintained with an appropriate level of servicing. As with any software driven system, data and files should be backed up on a regular basis and critical components should be identified and checked at regular intervals.

BMS functions such as trend data, reports and alarms should be used to perform maintenance by exception. Maintenance should be approached as the performance of the controlled system not individual components, i.e. AHU or chiller plant.

While the BMS equipment vendor should be utilised to maintain the critical components, other suitably qualified technicians can be utilised for field equipment.

For more information, contact Christopher Cobb, UWC, +27 (0)72 633 2339, [email protected]





Share this article:
Share via emailShare via LinkedInPrint this page



Further reading:

Partnership addresses fire hazard mitigation
Brigit Fire (a Division of Hudaco Trading) Elvey Security Technologies Fire & Safety Security Services & Risk Management
Brigit Fire has partnered with the Elvey Group. The collaboration will see Brigit Fire distributing both the advanced C-TEC addressable fire detection systems (CAST Technology) and GreenMist lithium extinguishers.

Read more...
Fire protection for a solvent extraction plant in Africa
FS Systems Fire & Safety Security Services & Risk Management Mining (Industry)
A prominent mining site operates a state-of-the-art solvent extraction (SX) plant, integral to separating and purifying metals from ores, which pose significant fire risks, as SX processes involve highly flammable organic solvents and elevated operating temperatures.

Read more...
Taking fire safety seriously
G2 Fire Editor's Choice Fire & Safety Security Services & Risk Management
To gain insights into how fire systems must be designed, installed and maintained, SMART Security Solutions asked Nichola Allan, MD of G2 Fire, for some insights into the local fire market.

Read more...
SMARTpod talks to The Risk Management Forum
SMART Security Solutions Editor's Choice News & Events Security Services & Risk Management Videos Training & Education
SMART Security Solutions recently released its first SMARTpod podcast, discussing the upcoming Risk Management Forum Conference 2024, which will be held on 26 September 2024 at the Indaba Conference Centre in Fourways, Johannesburg.

Read more...
There is a SaaS for everything, but at what cost, especially to SMEs?
Editor's Choice Information Security Security Services & Risk Management
Relying on SaaS platforms presents significant cybersecurity risks as the number of providers in your landscape increases, expanding your attack surface. It is important to assess the strength of the SaaS providers in your chain.

Read more...
Unlocking new efficiencies in private security
Security Services & Risk Management Transport (Industry) Smart Home Automation Logistics (Industry)
Justin Manson, Sales Director at Webfleet, discusses how the urgent need to protect life, and to do so more efficiently, is driving continuous innovation in holistic home and residential security services in South Africa.

Read more...
Innovation and security go hand in hand
Technews Publishing Facilities & Building Management Security Services & Risk Management
In a world where the demand for tech innovation is matched only by the acceleration of cybersecurity threats, businesses face the challenge of balancing new product development and robust security measures.

Read more...
Bomb threat landscape in South Africa
Editor's Choice Security Services & Risk Management
Over the past 25 years, South Africa has faced thousands of bomb threats and explosive incidents annually, imposing a significant economic burden on the nation, costing billions of rand.

Read more...
Natural catastrophes and fire risks top concerns
Security Services & Risk Management Asset Management Residential Estate (Industry)
Natural disasters are the highest risk in the real estate industry, followed by fire and explosions, and then business interruption. Estates must prioritise risk management and take proactive measures to safeguard their assets, employees, and reputation.

Read more...
Building a solid foundation
Alwinco Security Services & Risk Management Asset Management Residential Estate (Industry)
Understanding the roles of a Risk Assessor and a Risk Manager is like building a solid and secure foundation in the security world. Andre Mundell makes it easy to understand.

Read more...